Applied Spectroscopy · 2003 · 128 citations · 27 references
We investigated the applicability of Raman microprobe spectroscopy for determining the density of CO2 in fluid inclusions in minerals of mantle-derived xenolith samples. A separation (delta) between two Raman bands of CO2 due to Fermi resonance can be a reliable densimeter for CO2 fluid. The relationship between the density of CO2 (g/cm3) and delta (cm-1) can be expressed as: d = -0.03238697 delta 3 + 10.08428 delta 2 - 1046.189 delta + 36163.67. This equation was obtained from the Raman data on CO2 fluid with densities from 0.1 to 1.21 g/cm3, including super critical fluids at 58-59 degrees C. The delta value was constant with increasing temperature from room temperature to 200 degrees C. This indicates that the Raman densimeter is not affected by a possible rise in temperature, an artifact induced by the high flux of the incident laser. The minimum size of measurable inclusions is 1 micron, and the precision in the determination of delta is 0.1 cm-1, corresponding to 0.02 g/cm3 for inclusions of 1 micron in size. The precision can be better for larger inclusions. The micro-Raman densimeter can determine the density of CO2 fluid inclusions over a wide range. In particular, densities of gas and mixtures of gas and liquid phases, which cannot be measured by microthermometry, can be determined.
27
Fluid inclusions in mantle xenoliths
Tom Andersen, Else‐Ragnhild Neumann · Lithos · 2001 · 225 citations