Journal of Propulsion and Power · 2006 · 51 citations · 14 references
EngineeringMaterials EngineeringMaterials ScienceColloid ScienceMicrofabricationPropulsionElectric PropulsionElectrostatic SprayingIon PropulsionMicrofabrication MaterialsPropellant ChemistryDeep Reactive Ion EtchingElectrospray PropulsionElectrospray ThrustersField Loss ReductionFlow Rate DependenceReactive Ion EtchingShieldingTriangular Arrays
Microfabricated emitters have been produced by deep reactive ion etch technology. To demonstrate their suitability as components of integrated colloid thruster systems, the authors evaluated the electrospray performance of individual and arrays of these microfabricated emitters and compared them to conventional stainless‑steel emitters. The study assessed electrospray performance by measuring spray current dependence on flow rate for individual and arrayed microemitters and comparing the results to conventional emitters. The spray current of microemitters scales with flow rate similarly to conventional emitters, is independent of array size per nozzle, and the total current scales with nozzle count, triangular arrays show no shielding effects, and the ionic liquid 1‑butyl‑3‑methylimidazolium tetrafluoroborate demonstrates promising electrospray performance as a new colloid thruster propellant.
Microfabricated emitters have been produced by deep reactive ion etch technology. To demonstrate their suitability as components of integrated colloid thruster systems, we have evaluated the electrospray performance of individual and arrays of these microfabricated emitters and compared them to that of conventional stainless-steel emitters. We show that, after accounting for electrostatic differences caused by changes in physical geometry, the spray current dependence on flow rate for microemitters demonstrates similar scaling behavior to that of conventional single stainless-steel emitters. The spray current per nozzle is found to be independent of array size and the total spray current to depend simply on the number of nozzles in the emitter array. We have also found that in a triangular array of microemitters there is no significant geometry-induced shielding or field reduction between emitters. We report on the electrospray performance of the room- temperature ionic liquid 1-butyl-3-methylimidazolium tetrafluoroborate with conventional emitters, which appears to be a promising new colloid thruster propellant.
14
Electrostatic Spraying of Liquids
Adrian Bailey · Physics Bulletin · 1984 · 291 citations
Engineering, Chemical Engineering, Mechanical Engineering +10
C. D. Hendricks · Journal of Colloid Science · 1962 · 112 citations