IEEE Transactions on Power Apparatus and Systems · 1977 · 14 citations · 6 references
EngineeringElectrical EngineeringMechanical EngineeringElectric MachinesMachine DesignPower ElectronicsElectric MotorsInduction MachinesHysteresisInduction MotorsMachine Scaling LawsMotor EfficiencyMotor Efficiency AnalysisMotor Performance EvaluationMotor System EfficiencyPower Factor
This paper examines the possibilities of designing large, integral-horsepower hysteresis motors to have efficiency and power factor comparable with that of induction motors. Scaling techniques are used, together with a previously published analytical method, to scale up an existing laboratory hysteresis motor of 3 kW rating. The resulting design for a 200 kW hysteresis motor is predicted to have an efficiency in excess of 90% and a power factor in excess of 70%.
6