MedicineOncologyRadiation OncologyClinical Radiation OncologyRadiation DosimetryTreatment PlanningExternal Beam RadiotherapyIntensity-modulated RadiotherapyQuality Assurance In DosimetryRadiation TherapyRadiation Treatment PlanningTreatment Planning PhysicsBeam Delivery SystemsDose Verification SystemsFlattening Filter Free Beam DosimetryFlattening Filter-free BeamsPlan Quality AssessmentPretreatmentRadiotherapy Quality AssuranceTreatment Plan Evaluation
PURPOSE: Pretreatment quality assurance data from four centers, members of the European TrueBeam council were analyzed with different verification devices to assess reliability of flattening filter free beam delivery for intensity modulated radiotherapy (IMRT) and RapidArc (RA) techniques. METHODS: TrueBeam(®) (Varian Medical System) is a new linear accelerator designed for delivering flattened, as well as flattening filter free beams. Pretreatment dosimetric validation of plan delivery was performed with different verification devices and responses to high dose rates were tested. Treatment planning was done in Eclipse planning system (PRO 8.9, AAA 8.9). γ evaluation was performed with (dose difference) = 3% and (distance to agreement) = 3 mm scoring the gamma agreement index (GAI, % of field area passing the test). Two hundred and twenty-four patients with 1-6 lesions in various anatomical regions and dose per fraction ranging from 1.8 Gy to 25 Gy were included in the study; 88 were treated with 6 MV flattening filter free (X6FFF) beam energy and 136 with 10 MV flattening filter free (X10FFF) beam. Gafchromic films in solid water, delta(4), arccheck, and matrixx phantom were used to verify the dose distributions. Additionally, point measurements were performed using a PinPoint chamber and a Farmer chamber. RESULTS: Dose calculation as well as dose delivery was equally accurate for IMRT and RA delivery (IMRT: GAI = 99.3% (±1.1); RA: GAI = 98.8% (±1.1) as well as for the two beams evaluated (X6FFF: GAI = 99.1% (±1.0); X10FFF: GAI = 98.8% (±1.2). Only small differences were found for the four verification devices. A point dose verification was performed on 52 cases, obtaining a dose deviation of 0.34%. The GAI variations with number of monitor units were statistically significant. CONCLUSIONS: The TrueBeam FFF modality, analyzed with a variety of verification devices and planned with Eclipse planning system is dosimetrically accurate (within the specified limits 3 mm/3%) for both X6FFF and X10FFF beam energy.
23
Evaluation of the Delta<sup>4</sup>phantom for IMRT and VMAT verification
James L. Bedford, Young Lee, Philip Y. Wai et al. · Physics in Medicine and Biology · 2009 · 208 citations
Dosimetric characteristics of 6 and 10MV unflattened photon beams
G. Kragl, Sacha af Wetterstedt, Barbara Knäusl et al. · Radiotherapy and Oncology · 2009 · 165 citations
Jan Hrbáček, Stephanie Tanadini‐Lang, Stephan Klöck · International Journal of Radiation Oncology*Biology*Physics · 2010 · 150 citations