Is Systemic Heparin a Risk Factor for Catheter-Related Sepsis in Dialysis Patients?

Charles J. Diskin, Thomas J. Stokes, Linda M. Dansby, Lautrec Radcliff, Thomas B. Carter

Nephron Clinical Practice · 2007 · 33 citations · 19 references

Concepts

Abstract

BACKGROUND: Biofilms are dense aggregates of surface adherent microorganisms embedded in a polysaccharide matrix. Intravenous iron and heparin are thought to promote the formation of biofilm. Both are commonly employed during hemodialysis treatments which might affect the incidence of catheter-related sepsis. METHODS: 559 patients who underwent hemodialysis treatment with a catheter were reviewed. Episodes of sepsis were analyzed for the use of systemic heparin and intravenous iron as well as all other risk factors for sepsis. RESULTS: Sepsis developed in 141 of the 796 catheters. Analysis of variance revealed that the number of days that the catheter remained in place was the most significant variable (p < 0.0001) associated with catheter-related sepsis along with multiple other variables, but a Cox proportional hazards analysis revealed that only the two biofilm risk factors (intravenous iron [p < 0.001], and mid-treatment bolus of heparin [p = 0.046]) along with previously reported factor of a depressed serum albumin (p = 0.001) are of significance. CONCLUSION: In addition to duration of catheter use, we found three significant risk factors for sepsis and two of those three have been associated with the development of biofilm.

References

19