Journal of Scientific Instruments · 1962 · 28 citations · 3 references
Natural SciencesMaterials EngineeringMaterials ScienceActuatorsCeramic MaterialsCeramicsCeramic ProcessingCeramic TechnologyElectrical Properties Of CeramicsMotion ControlStructural CeramicsTransducer TechnologyBarium TitanateBarium Titanate CeramicsElectrical CeramicsMechanical TransducersStrontium Barium TitanateTransducer FabricationTransducer MaterialsVoltage
The construction and use of barium titanate ceramic transducers for fine-movement control is described. The movement obtainable for unit applied voltage is approximately 0.25 μm kv-1, a maximum working voltage per unit thickness of the ceramic of 3.5 kv mm-1 being possible. The maximum movement obtainable for a given overall voltage can be increased by lamination of the ceramics. Parallel movement of a plate is provided by the use of three transducers as supports; the expansions of such supports are identical to within 5 nm for a movement of 2.5 μm.