Diabetes Technology & Therapeutics · 2012 · 15 citations · 25 references
MedicineEndocrinologyInternal MedicineBioinstrumentationDiabetologySurgical InstrumentationBlood Glucose MonitoringContinuous Glucose MonitoringDiabetes ManagementDiabetes MellitusGlycemic MonitoringInsulin TherapyBlood Glucose RegulationC-peptide MeasurementContinuous Subcutaneous InfusionContinuous Subcutaneous Insulin InfusionGlucose MonitoringGlucose QuantificationInsulin Injection TechniqueInterstitial Glucose Measurement
BACKGROUND: Treatment of type 1 diabetes patients could be simplified if the site of subcutaneous insulin infusion could also be used for the measurement of glucose. This study aimed to assess the agreement between blood glucose concentrations and glucose levels in the interstitial fluid (ISF) that is extracted from the insulin infusion site during periodic short-term interruptions of continuous subcutaneous insulin infusion (CSII). SUBJECTS AND METHODS: A perforated cannula (24 gauge) was inserted into subcutaneous adipose tissue of C-peptide-negative type 1 diabetes subjects (n=13) and used alternately to infuse rapid-acting insulin (100 U/mL) and to extract ISF glucose during a fasting period and after ingestion of a standard oral glucose load (75 g). RESULTS: Although periodically interrupted for extracting glucose (every hour for approximately 10 min), insulin infusion with the cannula was adequate to achieve euglycemia during fasting and to restore euglycemia after glucose ingestion. Furthermore, the ISF-derived estimates of plasma glucose levels agreed well with plasma glucose concentrations. Correlation coefficient and median absolute relative difference values were found to be 0.95 and 8.0%, respectively. Error grid analysis showed 99.0% of all ISF glucose values within clinically acceptable Zones A and B (83.5% Zone A, 15.5% Zone B). CONCLUSIONS: Results show that ISF glucose concentrations measured at the insulin infusion site during periodic short-term interruptions of CSII closely reflect blood glucose levels, thus suggesting that glucose monitoring and insulin delivery may be performed alternately at the same tissue site. A single-port device of this type could be used to simplify and improve glucose management in diabetes.
25
Transdermal monitoring of glucose and other analytes using ultrasound
Joseph Kost, Samir Mitragotri, Robert A. Gabbay et al. · Nature Medicine · 2000 · 252 citations
Accuracy of the 5-Day FreeStyle Navigator Continuous Glucose Monitoring System
Richard L. Weinstein, Sherwyn Schwartz, Ronald Brazg et al. · Diabetes Care · 2007 · 227 citations