Medical Physics · 2004 · 135 citations · 38 references
MedicineRadiologyRadiation DosimetryRadiation MeasurementTreatment PlanningAbsorbed DoseExternal Beam DosimetryMonte Carlo DosimetryRadiation Dose MeasurementRadiation Imaging DetectorsTreatment Planning Dose CalculationAmorphous SiliconBackscatteringDetector ModelingElectronic Portal ImagingEnergy DepositionMonte Carlo Dose SimulationSilicon Detector DosimetrySilicon Dosimetry
This study develops and tests a method to compute dosimetric images for an amorphous silicon (a-Si) flat-panel detector so that an accurate quantitative comparison between measured and computed portal images may be made. An EGS4-based Monte Carlo (MC) algorithm is developed to efficiently tally the energy deposition through the use of a virtual detector dose-scoring methodology. The complete geometry of the a-Si imager is utilized in the MC calculation up to the imager rear housing, which is replaced with a uniform thickness material slab. The detector-mounting hardware is modeled as a uniform backscattering material. The amount of backscatter material required to reproduce the measured backscatter is 0.98 g/cm2 of water. A flood-field irradiation, performed in the measurement imaging session, is used to cross-calibrate the computed images with the measured images. Calibrated MC-computed images reproduce measured field-size dependencies of the electronic portal imaging device (EPID) response to within <1%, without the need for optical glare or other empirical corrections. A 10% dose difference between measured and computed images was observed outside the field edge for a 10 x 10 cm2 field that was entirely blocked by the multileaf collimator (MLC). However, this error corresponded with less than 0.15% of the open-field dose. For 10 x 10 cm2 fields produced by 5 and 20 mm dynamically sweeping MLC gaps, more than 98% of the points were found to have a gamma less than one with a 2%, 2 mm criteria. For an intensity modulated radiation therapy (IMRT) patient test field, over 99% of the points were found to have a gamma less than one with a 2%, 2 mm criteria. This study demonstrates that MC can be an effective tool for predicting measured a-Si portal images and may be useful for IMRT EPID-based dosimetry.
38
A technique for the quantitative evaluation of dose distributions
Daniel A. Low, William B. Harms, Sasa Mutic et al. · Medical Physics · 1998 · 2.9K citations · Full text
BEAM: A Monte Carlo code to simulate radiotherapy treatment units
D. W. O. Rogers, Bruce Faddegon, G Ding et al. · Medical Physics · 1995 · 1.4K citations
Monte Carlo simulation of electron beams from an accelerator head using PENELOPE
Josep Sempau, A. Sánchez‐Reyes, F. Salvat et al. · Physics in Medicine and Biology · 2001 · 235 citations
Medicine, Physics, Medical Physics +16