Accurate noise measurements of superconducting quasiparticle array mixers

W. R. McGrath, Antti V. Räisänen, P. L. Richards, R. Harris, F. L. Lloyd

IEEE Transactions on Magnetics · 1985 · 37 citations · 5 references

Concepts

Abstract

We have constructed a 30-40 GHz test apparatus which allows us to measure the noise temperatures of SIS mixers with an accuracy of better than ±1K. This is a factor of six improvement over earlier measurements. The most accurate measurement made thus far of a mixer which uses a single Pb-alloy junction yielded T <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">m</inf> = 9.2 ± 0.9 K; and mixer gain: G <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">m</inf> = 0.240 ± 0.005. In addition, SIS mixers employing arrays of N = 1, 5, 10, 25, and 50 tunnel junctions in series have been tested. The input power required to saturate the array mixers was found to increase as N <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> and the gain and noise temperature of the array mixers were independent of N.

References

5