Applied Physics Letters · 1972 · 34 citations · 8 references
EngineeringElectrical EngineeringMaterials ScienceOptoelectronicsRadiation DetectionSpectroscopyAbsorption SpectroscopyDetector TechnologyOptical DetectorsPhotodetectorsRadiation DetectorsSemiconductor DetectorsBurn IntensityMaximum OutputPyroelectric DetectorsPyroelectric MaterialsPyroelectric PropertiesPyroelectricitySpectral Response CharacterizationThermal Detectors
We have designed and tested a 500-psec-rise-time pyroelectric detector. The responsivity is great enough to drive a Tektronix 519 oscilloscope when amplified with a 1.0-GHz-bandwidth amplifier. To obtain broad spectral response we have developed a thermally fast-absorbing black which has approximately 50% absorption from 0.3 μ to greater than 50 μ, and transfers 90% of the absorbed energy to the pyroelectric crystal in 400 psec. The maximum detector output voltage prior to amplification is 2. 0 V, limited by the absorbing black's burn intensity.
8
Optical Generation of Intense Picosecond Electrical Pulses
D. H. Auston, A. M. Glass · Applied Physics Letters · 1972 · 75 citations