IEEE Transactions on Biomedical Circuits and Systems · 2014 · 49 citations · 15 references
EngineeringBiomedical EngineeringElectrical EngineeringAnalog ElectronicsBiomedical Signal ProcessingElectrophysiologyBiomedical InstrumentationCardiac PacingElectrocardiographyIntracardiac ElectrophysiologyMedical InstrumentationPhysiological Signal AcquisitionArrhythmia DetectionCardiac Sensing DevicesElectrocardiography InstrumentationHeartbeat MonitoringInput NoiseInput-referred NoiseLeadless PacemakersSingle-chamber Pacing
A sub- μW ECG acquisition IC is presented for a single-chamber leadless pacemaker applications. It integrates a low-power, wide dynamic-range ECG readout front end together with an analog QRS-complex extractor. To save ASIC power, a current-multiplexed channel buffer is introduced to drive a 7 b-to-10 b self-synchronized SAR ADC which utilizes 4 fF/unit capacitors. The ASIC consumes only 680nA and achieves CMRR > 90 dB, PSRR > 80 dB, an input-referred noise of 4.9 μVrms in a 130 Hz bandwidth, and has rail-to-rail DC offset rejection. Low-power heartbeat detections are evaluated with the help of the ASIC acquiring nearly 20,000 beats across 10 different records from the MIT-BIH arrhythmia database. In the presence of muscle noise, both the average Sensitivity (Se) and Positive Predictivity (PP) show more than 90% when the input SNR > 6 dB.
15
PhysioBank, PhysioToolkit, and PhysioNet
Ary L. Goldberger, Luı́s A. Nunes Amaral, Leon Glass et al. · Circulation · 2000 · 14.5K citations · Full text
Ira Krepchin · Datamation · 1993 · 381 citations