Tomography using monochromatic thermal neutrons with attenuation and phase contrast

F. Dubus, U. Bonse, Theodor Biermann, Matthias Baron, Felix Beckmann, M. Zawisky

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2002 · 11 citations · 12 references

Concepts

Abstract

Attenuation-contrast tomography with monochromatic thermal neutrons was developed and operated at guide station S18 of the institute Laue-Langevin in Grenoble. From the S18 spectrum the neutron wavelength (lambda) equals 0.18 nm was selected by employing a fore crystal with the silicon 220 reflection at a Bragg angle (Theta) equals 30 degrees. Projections were registered by a position sensitive detector (PSD) consisting of a neutron-to-visible-light converter coupled to a CCD detector. Neutron tomography and its comparison with X-ray tomography is studied. This is of special interest since the cross section for neutron attenuation ((sigma) <SUB>atom</SUB>) and the cross section for neutron phase shift (b<SUB>c</SUB>) are isotope specific and, in addition, by no means mostly monotonous functions of atomic number Z as are attenuation coefficient ((mu) <SUB>x</SUB>) and atomic scattering amplitude (f) in the case of X-rays. Results obtained with n-attenuation tomography will be presented. Possibilities and the setup of an instrument for neutron phase-contrast tomography based on single-crystal neutron interferometry will be described.

References

12