Phase-Locked Loop DC Motor Drive with Improved Transient Performance

K. Eapen, K. Venkatesan

IEEE Transactions on Industrial Electronics and Control Instrumentation · 1981 · 11 citations · 7 references

Concepts

Abstract

A method to stabilize a phase-locked loop (PLL) dc motor control system is described. Integral square error (ISE) criterion is used to find out the constants of the stabilizing circuit for giving an optimum response. Transient response of the system is calculated for a sudden loading condition and changes in reference frequency. Experimental oscillograms are also included.

References

7