Engineered nanoparticles require validated analytical tools for regulatory risk assessment, particularly for measuring absolute mass concentration and dissolved fractions of metal‑based ENPs in toxicity studies. The study compares simple off‑line methods to determine total concentrations of five metal‑based ENP suspensions and to quantify the dissolved fraction of an Ag ENP suspension. Total concentrations were measured by ICP‑MS using direct measurement, acidification, and microwave‑assisted digestion. Direct ICP‑MS measurements underestimated total ENP concentrations compared to digestion, while acidified suspensions yielded higher recoveries; among dissolved‑fraction methods, ultrafiltration combined with microwave digestion emerged as the best practice due to precision, speed, applicability, and cost.

Abstract

Validated and easily applicable analytical tools are required to develop and implement regulatory frameworks and an appropriate risk assessment for engineered nanoparticles (ENPs). Concerning metal-based ENPs, two main aspects are the quantification of the absolute mass concentration and of the "dissolved" fraction in, e.g., (eco)toxicity and environmental studies. To provide information on preparative aspects and on potential uncertainties, preferably simple off-line methods were compared to determine (1) the total concentration of suspensions of five metal-based ENP materials (Ag, TiO2, CeO2, ZnO, and Au; two sizes), and (2) six methods to quantify the "dissolved" fraction of an Ag ENP suspension. Focusing on inductively coupled plasma-mass spectrometry, the total concentration of the ENP suspensions was determined by direct measurement, after acidification and after microwave-assisted digestion. Except for Au 10 nm, the total concentrations determined by direct measurements were clearly lower than those measured after digestion (between 61.1 % for Au 200 nm and 93.7 % for ZnO). In general, acidified suspensions delivered better recoveries from 89.3 % (ZnO) to 99.3 % (Ag). For the quantification of dissolved fractions two filtration methods (ultrafiltration and tangential flow filtration), centrifugation and ion selective electrode were mainly appropriate with certain limitations, while dialysis and cloud point extraction cannot be recommended. With respect to precision, time consumption, applicability, as well as to economic demands, ultrafiltration in combination with microwave digestion was identified as best practice.

References

48