Optics Letters · 2000 · 16 citations · 8 references
Natural SciencesChemistryAtmospheric ChemistryPhotonicsSpectroscopyAbsorption SpectroscopyAtmospheric AbsorptionInfrared SpectroscopyLaser SpectroscopyMicrowave SpectroscopyOptical SpectroscopyAbsorption SpectraCavity Ring-down SpectroscopyDetection Limit AssessmentInfrared Absorption SpectroscopyInstrument Detection LimitMethod Detection LimitMid-infrared InstrumentationSpectroscopic Detection
We report on spectroscopic real-time detection of (13)CH(4) in ambient air. Our measurements were carried out by means of cavity leak-out absorption spectroscopy employing a tunable cw laser in the mid-infrared spectral region near lambda = 3 microm. A CO laser in combination with tunable microwave sideband generation was used as the light source. Using a 50-cm-long ringdown cell with R = 99.98% mirrors, we achieved a detection limit of 290 parts in 10(12) (ppt) (13)CH(4) in ambient air (integration time, 100 s). The corresponding noise-equivalent absorption coefficient was 5 x 10(-9)/cm.
8
Paul J. Crutzen · Nature · 1991 · 278 citations
P. Bergamaschi, M. Schupp, G. W. Harris · Applied Optics · 1994 · 126 citations