SPE Production & Facilities · 2004 · 10 citations · 0 references
EngineeringCivil EngineeringPetroleum EngineeringHeat TransferHydraulicsWater Resources EngineeringHydrate ControlHydrate PreventionMultiphase Flow In PipelinesPipeline SystemsSubsea PipelinesDirect HeatingEquilibrium TemperatureHydrate Formation In PipelinesHydrate Formation PreventionHydrate RemediationMultiphase Hydrate FormationPipeline Hydrate ControlPipelines
Summary The novel technique of applying electrical heat to prevent hydrate formation in multiphase pipelines has been applied successfully on the Norwegian continental shelf. The first pipelines in which direct electrical heating (DEH) was applied have recently been put into operation. DEH is based on applying electrical current through the steel wall of the pipeline, generating heat through wall resistance. By applying DEH, the fluid temperature can be maintained at greater than the hydrate equilibrium temperature (HET). Operational experience has proven that the concept is successful with regard to temperature control. It has been shown that the DEH system is capable of heating the pipeline inventory from the seabed temperature to one greater than the HET. The DEH system installed on the Huldra-Veslefrikk condensate pipeline is described in detail here. This is an 8-in. pipeline with a length of 16 km. The application of the DEH system with respect to hydrate prevention and possible hydrate remediation is also discussed in detail.