Applied Physics Letters · 2011 · 22 citations · 13 references
Natural SciencesBiomedical EngineeringRadiologyDiagnostic ImagingDiagnostic RadiologyOpticsInterferometryRadiographic ImagingScintillation DetectorsX-ray DetectionX-ray DetectorsX-ray OpticsContrastFringe AnalysisFringe VisibilityPenetration DepthRadiation Penetration DepthRadiographic Image QualityX-ray Imaging OpticsX-ray Interferometry
Grating interferometry at conventional x-ray tubes improves the quality of radiographies and tomograms by providing phase and scattering contrast data. The main challenge encountered when applying this technique at high photon energies, as required by many applications to obtain sufficient penetration depth, is to maintain a high fringe visibility. In this letter, we report on a substantial improvement in fringe visibility and according improvements in image quality achieved by replacing the absorbing analyzer grating of the interferometer with a structured scintillator grating. This development represents a significant step toward the implementation of this technique in industrial testing and medical applications.
13
X-ray phase imaging with a grating interferometer
Timm Weitkamp, Ana Díaz, Christian Dávid et al. · Optics Express · 2005 · 1.2K citations · Full text
Hard-X-ray dark-field imaging using a grating interferometer
Franz Pfeiffer, Martin Bech, Oliver Bunk et al. · Nature Materials · 2008 · 1.1K citations
Natural Sciences, Physics, Radiology +14
Differential x-ray phase contrast imaging using a shearing interferometer
Christian Dávid, B. Nöhammer, H. H. Solak et al. · Applied Physics Letters · 2002 · 619 citations
Richard Fitzgerald · Physics Today · 2000 · 554 citations · Full text