Comparative Study of PMSM Drive Systems Based on Current Control and Direct Torque Control in Flux-Weakening Control Region

Yuki Inoue, Shigeo Morimoto, Masayuki Sanada

IEEE Transactions on Industry Applications · 2012 · 147 citations · 12 references

Concepts

Abstract

This paper examines the control performance of permanent-magnet synchronous motor drive systems based on current control and direct torque control (DTC) when flux-weakening control is applied. The control law in the <i xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">M</i> - <i xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">T</i> frame, which is used in the DTC, requires only armature resistance, whereas the control law in the <i xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">d</i> - <i xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">q</i> frame, which is used in current control, requires many motor parameters for flux-weakening control. The experimental results clarify the influence of parameter variation on the control characteristics of flux weakening and torque limiting. The DTC-based motor drive system combined with the control laws in the <i xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">M</i> - <i xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">T</i> frame has several advantages, including insensitivity to parameter variation, simplicity of calculation, and stable control.

References

12