Iliac Lymph Node Aspiration Biopsy Through Paravascular Approach; Preliminary Report

A Rüttimann

Radiology · 1968 · 19 citations · 0 references

Concepts

Abstract

Lymphography can be used to localize a disease process in iliac lymph nodes. In an enlarged lymph node it is often impossible to establish an accurate diagnosis by other means, and in selected cases needle aspiration biopsy following lymphography may be desirable for this purpose. Technic The percutaneous puncture site is the inguinal region adjacent to the femoral artery and femoral vein. If the iliac lymph node to be punctured lies medial or dorsal to the vessels (nodi lymphatici iliaci externi mediales, nodi lymphatici intermedii dorsales), a puncture site just medial to the femoral vein is chosen. For lymph nodes lying ventral or lateral to the vessels (nodi lymphati ciiliaci externi laterales, intermedii anteriores) a puncture site lateral or ventral to the femoral artery is preferable. Local infiltration anesthesia of the skin and subcutaneous tissue is first accomplished. The puncture is performed under fluoroscopic television control. A thin needle (0.6 mm) is directed along the vessels through the lacuna vasorum toward the lymph node. Continuous injection of the local anesthetic provides a smooth paravascular channel. The peritoneum is separated from the edge of the pelvis by the injection of the anesthetic. The needle may easily be directed to the lymph node to be punctured by rotating the patient to both sides during the procedure. When the needle for the anesthesia reaches the node, the puncture needle is directed to the same place just parallel to it, and the trajectory of the needle is checked again by turning the patient on a cradle under television fluoroscopy. Movement of the node with movement of the needle indicates accurate location of the needle tip (Fig. 1). The first needle is then withdrawn, and the puncture needle (side-hole closed) is then introduced into the node. The side-hole is opened by turning the obturator under forced aspiration. Lymph node material will be aspirated as a result of the negative pressure created. After the side-hole is closed the needle is withdrawn. The biopsy material is fixed in a 4 per cent formalin solution and analyzed by the histologist or cytologist. Results Our series (12 cases) is too small to make any definite conclusion concerning the value of the procedure. In one case the puncture needle could not be accurately directed, because the nodes were difficult to identify fluoroscopically owing to inadequate opacification. In another case the material obtained was not sufficient to establish a definite histological diagnosis. In the 10 other cases a histological diagnosis could be established. Complications No significant complications were encountered. However, when the puncture site was lateral to the femoral vessels (1 case), the femoral and the genitofemoral nerves were infiltrated by the anesthetic, and slight transient motor and sensory impairment was observed. Therefore we afterward avoided the lateral approach.