Otolaryngology · 2001 · 21 citations · 4 references
MedicineOtolaryngologySurgeryCochlear ImplantsOtologyVestibular AssessmentNeuro-otologic ExaminationVestibular FunctionVestibular NeuroscienceVestibular PhysiologyVestibular SystemVestibular TestingCanal ParesisCochlear Implant StimulationInner Ear SurgeryVestibular Function Monitoring
INTRODUCTION: The computer-based ENG system's analytical routine refinements are available only in research laboratories. The computer-based system contains a stimulator for saccadic eye-movement and an air caloric stimulator interconnected to the registration program and analysis software. Several authors have reported the preoperative and postoperative vestibular functions in cochlear implant patients. The safe examination of the operated ear and comparison of the preoperative and postoperative average slow phase velocities of the caloric nystagmus is possible using the air caloric computer system. METHODS: The authors have used a computer-based ENG system with caloric air stimulation, which is very useful for examination of the operated ear. The vestibular system of patients with total deafness was examined before and after the cochlear implantation. The results of 60 vestibular examinations of 64 patients are reported. RESULTS: The vestibular function in the operated ear was found unchanged in 20 patients. In 14 patients the vestibular function was worse. In 16 patients the postoperative vestibular responsiveness improved. The detailed data analysis of 10 patients in whom preoperative and postoperative vestibular examination was similar was performed by the authors. The preoperative and postoperative average slow phase velocity values and the relative canal paresis was observed. The values demonstrated that the caloric responsiveness of the operated ear improved in few cases. CONCLUSIONS: The computer-based air caloric system is a useful and safe method in evaluation of the vestibular system changes after ear surgery. The reason of the improvement of vestibular responsiveness is not clear. The results need further investigation to solve the problem of vestibular responsiveness improvement after cochlear implantation.
4
Vestibular effects associated with implantation of a multiple channel cochlear prosthesis.
Robert H. Brey, George W. Facer, M B Trine et al. · PubMed · 1995 · 92 citations
Medicine, Otolaryngology, Surgery +17
Vestibular Function in Cochlear Implant Patients
Paul van den Broek, P.L.M. Huygen, Lucas H. M. Mens et al. · Acta Oto-Laryngologica · 1993 · 42 citations
Medicine, Audiology, Otolaryngology +17
Vestibular Function and Cochlear Implant
Giovanni Rossi, P. Solero, Marco Rolando et al. · ORL · 1998 · 25 citations
Medicine, Otolaryngology, Surgery +17