Direct measurement of the energy spectrum of an intense proton beam

R. J. Leeper, J. R. Lee, Lynn Kissel, D. J. Johnson, W. A. Stygar, D. E. Hebron

Journal of Applied Physics · 1986 · 29 citations · 4 references

Concepts

Abstract

A time-resolved magnetic spectrograph was used to measure the energy spectrum of an intense (0.7 TW/cm2) proton beam. A thin gold foil placed at the focus of an ion-diode Rutherford-scattered protons by 90° into the spectrograph, reducing the beam intensity to a level suitable for magnetic analysis. The scattered protons were collimated and then deflected in a samarium-cobalt permanent magnet. The deflected protons were recorded simultaneously on CR-39 and eight p-i-n diodes. A Monte Carlo computer code was used to calculate the sensitivity and resolution of the spectrograph. Data taken on the Proto I accelerator shows a 150–250-keV-wide proton-energy spectrum at each instant in time.

References

4