Cryogenic requirements for the JT-60SA Tokamak

F. Michel, D. Hitz, Christine Hoa, Valerie Lamaison, Koji Kamiya, Pascal Roussel, Manfred Wanner, K. Yoshida

AIP conference proceedings · 2012 · 24 citations · 0 references

DOIFull text

Open access

Concepts

Abstract

The superconducting tokamak JT-60SA is part of the Broader Approach Programmeagreed between Japan and Europe. CEA is in charge of the cryogenic system procurementincluding the Warm Compression Station, the gas storages, the Refrigerator Cold Box andthe Auxiliary Cold Box (ACB) which has to be installed on the JAEA Naka site in 2016.This paper summarizes the updated cryogenic requirements for the tokamak JT-60SAcryogenic system. The cryogenic system has a refrigeration capacity of about 9 kW equivalent at 4.5K, to supply cryopump panels at 3.7 K, superconducting magnets and cold structures at 4.4 K, HTS current leads at 50 K, and thermal shields at 80 K. This paper presents the static and variable heat loads of the different cooling loops and the results of the rmohydraulic calculations to derive the transient heat loads at the interface between the magnet system cooling loops and the Auxiliary Cold Box.