Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2009 · 142 citations · 0 references
EngineeringElectrical EngineeringMaterials ScienceOptical MaterialsOptoelectronicsSemiconductor MaterialsInterferometryOptical InstrumentationOptical Properties Of SemiconductorsSemiconductor Device MaterialsTemperature MeasurementThermal Properties Of SemiconductorsAbsorptive MaterialsExperimental Data CollectionMid-infrared InstrumentationMid-infrared MaterialsThermal CalibrationThermal Effects In Photonic Devices
The PCI technique, a modification of photothermal spectroscopy, has become a powerful tool for testing various low absorptive optical materials and components. The current state of the technique and recent progress in extending its capabilities toward the mid-infrared region is presented. A 3.39 μm probe was used for testing and studying various semiconductor materials, such as p-doped GaAs, that can exhibit non-thermal response to the pump beam in addition to the thermal one. A simple theoretical model of the PCI method is shown to describe adequately the experimental data, making it possible to calibrate the setup without using a calibration standard.