Hydraulics of laboratory and full‐scale upflow anaerobic sludge blanket (UASB) reactors

Damien J. Batstone, John Hernandez, Jens Ejbye Schmidt

Biotechnology and Bioengineering · 2005 · 58 citations · 9 references

Concepts

Abstract

Laboratory-scale upflow anaerobic sludge blanket (UASB) reactors are often used as test platforms to evaluate full-scale applications. However, for a given volume specific hydraulic loading rate and geometry, the gas and liquid flows increase proportionally with the cube root of volume. In this communication, we demonstrate that a laboratory-scale reactor had plug-flow hydraulics, while a full-scale reactor had mixed flow hydraulics. The laboratory-scale reactor could be modeled using an existing biochemical model, and parameters identified, but because of computational speed with plug-flow hydraulics, mixed systems are instead recommended for parameter identification studies. Because of the scaling issues identified, operational data should not be directly projected from laboratory-scale results to the full-scale design.

References

9