Physics of Plasmas · 2003 · 53 citations · 20 references
Natural SciencesElectrical EngineeringPhysicsElectromagneticsElectromagnetismPlasma PhysicsPlasma ConfinementPlasma SourcesX-ray ProductionX-ray ShieldingGeneratorsInductive Power TransferInner ArrayOuter ArrayPlasma X-ray SourcesSelf-inductanceZ-pinch Plasmas
Nested wire array Z-pinch experiments carried out on the MAGPIE generator (1.4 MA, 240 ns) [I. H. Mitchell et al., Rev. Sci. Instrum. 67, 1553 (1996)] are described. In the experiments, a high inductance connection to the inner array was used to suppress the current flowing through it. This allowed the current division expected in experiments on larger generators to be emulated, where the number of wires in the outer array acts to shield the inner array. Initially the suppression of current resulted in the wires of the inner array remaining as small discrete bodies, while the wires of the outer array ablated, prefilling the array with plasma in an identical way to a single array experiment. During implosion the outer array accelerated towards the inner array, snowploughing up the prefilled plasma, producing a rise in x-ray emission. When the outer array traveled past the inner array, a fast inductive transfer of current occurred between them, and the inner array then accelerated towards the axis where it stagnated to produce the main x-ray pulse. The risetime of the main x-ray pulse was significantly shorter than in single array experiments. The dependence of the shape of the x-ray pulse on the configuration of the outer and inner arrays was explored.
20
Tungsten wire-array Z-pinch experiments at 200 TW and 2 MJ
R. B. Spielman, C. Deeney, G. A. Chandler et al. · Physics of Plasmas · 1998 · 585 citations
C. Deeney, M. R. Douglas, R. B. Spielman et al. · Physical Review Letters · 1998 · 344 citations
Effect of discrete wires on the implosion dynamics of wire array Z pinches
S. V. Lebedev, F. N. Beg, S. N. Bland et al. · Physics of Plasmas · 2001 · 318 citations