Journal of Instrumentation · 2013 · 35 citations · 3 references
EngineeringElectrical EngineeringNuclear EngineeringMicroelectronicsNuclear InstrumentationRadiation DetectionDetector TechnologyInstrumentation AmplifiersLow-noise Circuit DesignNoise In Electronic DevicesSemiconductor DetectorsDetector DesignDetectorsDiamond DetectorsLow-noise AmplificationLow-noise AmplifiersLow-noise DesignLow-noise Detector DesignLow-noise Operational Amplifiers
The new high energy high luminosity experiments require an improvement in \nboth the counting rate and the space resolution for the detectors. This improvement can be \nachieved by reducing the charge per count, however this implies a need for a better signal to \nnoise ratio in the signal processing. In this article we will show the performances of diamond \ndetectors and RPCs using a new preamplifier with low noise (500–1000 electrons RMS), \nfast shaping (about 10 ns) and large input capacitance.
3