Angular Distribution of Bremsstrahlung from Copper and Tungsten Targets Bombarded by 18, 28, and 38MeV Electrons
21
Citations
16
References
2010
Year
EngineeringBeamstrahlungRadiation TestingAngular DistributionElectron SpectroscopyCalibrationInstrumentationIon EmissionRadiation OncologyRateradiotherapylinacmonte CarlomcnpelectronRadiologyBremsstrahlung PhotonsRadiation DetectionPhysicsTungsten Targets BombardedAtomic PhysicsDosimetryHokkaido UniversityExperimental Nuclear PhysicsApplied PhysicsRadiation DoseDetector PhysicMedicineParticle Accelerator
Abstract We measured the angular distribution of bremsstrahlung photons between 0 and 120 degrees from copper and tungstentargets bombarded by 18, 28, and 38MeV electrons at the electron linac of Hokkaido University. Activation detectors and two types of dosimeters were applied for the measurement. The measured results were compared with those calculated with the Monte Carlo code MCNP5 to verify the calculated results. The calculated results of both the reaction rates and ambient dose equivalent rates gave good agreement with the measured ones in the case of 18MeV electrons. A good agreement between the measurement and calculation was also observed for relative angular distributions of dose rates from 38MeV electrons; however, the calculation overestimated the measured data by a factor of 1.2 to 2.0. To achieve further accuracy of calculation, improvement of photonuclear reaction data and absorbed dose measurement are necessary for bremsstrahlung radiation dosimetry. KEYWORDS: bremsstrahlungangular distributionactivation foilreaction ratedose rateradiotherapylinacMonte CarloMCNPelectron
| Year | Citations | |
|---|---|---|
1993 | 5.1K | |
1985 | 511 | |
1999 | 345 | |
1956 | 101 | |
1998 | 86 | |
2008 | 77 | |
1991 | 71 | |
1968 | 64 | |
1990 | 63 | |
1951 | 62 |
Page 1
Page 1