American Journal of Roentgenology · 2004 · 98 citations · 31 references
MedicineOncologyRadiologyDiagnostic ImagingDiagnostic RadiologyThoracic ImagingCancer DetectionChest RadiographyComputed TomographyComputer-aided DiagnosisLung CancerMedical ImagingCathode Ray Tube DisplaysGround-glass Opacity AssessmentGround-glass Opacity PatternsLinear Discriminant AnalysisMalignancy Probability EstimationOpacityPulmonary Nodule DiagnosisReceiver Operating Characteristic Analysis
OBJECTIVE: The purpose of our study was to evaluate whether a computer-aided diagnosis (CAD) scheme can assist radiologists in distinguishing small benign from malignant lung nodules on high-resolution CT (HRCT). MATERIALS AND METHODS: We developed an automated computerized scheme for determining the likelihood of malignancy of lung nodules on multiple HRCT slices; the likelihood estimate was obtained from various objective features of the nodules using linear discriminant analysis. The data set used in this observer study consisted of 28 primary lung cancers (6-20 mm) and 28 benign nodules. Cancer cases included nodules with pure ground-glass opacity, mixed ground-glass opacity, and solid opacity. Benign nodules were selected by matching their size and pattern to the malignant nodules. Consecutive region-of-interest images for each nodule on HRCT were displayed for interpretation in stacked mode on a cathode ray tube monitor. The images were presented to 16 radiologists-first without and then with the computer output-who were asked to indicate their confidence level regarding the malignancy of a nodule. Performance was evaluated by receiver operating characteristic (ROC) analysis. RESULTS: The area under the ROC curve (Az value) of the CAD scheme alone was 0.831 for distinguishing benign from malignant nodules. The average Az value for radiologists was improved with the aid of the CAD scheme from 0.785 to 0.853 by a statistically significant level (p = 0.016). The radiologists' diagnostic performance with the CAD scheme was more accurate than that of the CAD scheme alone (p < 0.05) and also that of radiologists alone. CONCLUSION: CAD has the potential to improve radiologists' diagnostic accuracy in distinguishing small benign nodules from malignant ones on HRCT.
31
Early Lung Cancer Action Project: overall design and findings from baseline screening
Claudia I. Henschke, Dorothy I. McCauley, David F. Yankelevitz et al. · The Lancet · 1999 · 2.5K citations · Full text
Mass screening for lung cancer with mobile spiral computed tomography scanner
Shusuke Sone, Shodayu Takashima, Feng Li et al. · The Lancet · 1998 · 942 citations
Claudia I. Henschke, David F. Yankelevitz, Rosna Mirtcheva et al. · American Journal of Roentgenology · 2002 · 911 citations
Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography.
Masahiro Kaneko, K. Eguchi, Hironobu Ohmatsu et al. · Radiology · 1996 · 841 citations