Concepedia

Publication | Closed Access

Single Open-phase Fault Detection with Fault-Tolerant Control of an Inverter-fed Permanent Magnet Synchronous Machine

16

Citations

29

References

2014

Year

Abstract

In this paper first a current predictive method for single open-phase fault detection in a three phase drive with a permanent magnet synchronous machine is presented. The proposed method is based on a predictive stator current calculation. For each sampling interval the difference between the actual stator current and its predicted value in a previous sampling interval is calculated. To identify the location of a single open-phase fault, an identification method is presented which is based on the analysis of the stator current vector angle. After the single open-phase fault is detected and identified it is desirable for the electrical machine to continue operating with a reduced number of phases. For this purpose, a modified direct torque control algorithm for the fault-tolerant control is implemented. In order to improve the performance of the drive, a pre-firing angle is additionally introduced. All proposed methods have been simulated in Matlab/Simulink and verified on an experimental model.

References

YearCitations

Page 1