Journal of Physics E Scientific Instruments · 1987 · 36 citations · 9 references
EngineeringMaterials ScienceMechanical EngineeringInstrumentationMetrologySensorsFlow MeasurementFlow MetrologyFlow SensorsMass MeasurementMechanical MeasurementPneumatic SystemsGamma-ray AttenuationMagnetic ResonanceMass Flow MeasurementMass Flow RateNonintrusive Flow MeasurementNonintrusive MeasurementPneumatic ConveyingPneumatic Conveying Systems
Mass flow measurement of pneumatically conveyed solids is challenging, with many approaches, and true mass flow meters rely on Coriolis or gyroscopic principles. The authors review nonintrusive instruments and discuss true and inferential mass flowmeters. They examine nonintrusive instruments, including true mass flowmeters and several inferential systems. Gamma attenuation offers advantages at high pressures but has limited resolution and speed, electrical capacitance devices are widely used yet prone to field‑uniformity errors, and magnetic resonance is useful for NMR materials but costly.
Mass flow measurement of pneumatically conveyed solids presents a range of problems resulting in many different approaches to the measurement system. The authors review nonintrusive instruments and discuss true mass flowmeters and inferential mass flowmeters. True mass flow meters are based upon either the Coriolis or the gyroscopic principle. Several inferential systems are considered. Gamma attenuation has advantages at high operating pressures but has limited resolution and restricted speed of response. Electrical capacitance devices are widely used but field uniformity problems may introduce errors. Magnetic resonance is useful for materials which exhibit NMR properties but is relatively expensive.