Superconductor Science and Technology · 2004 · 87 citations · 8 references
Natural SciencesElectrical EngineeringMaterials ScienceElectromagnetismInstrumentationSensorsCurrent Measurement InstrumentsElectrical CharacterizationElectrical ConductivityElectrical MeasurementMagnetic CharacterizationSuperconducting Thin FilmsCritical Current DensityCurrent-voltage CharacterizationHigh-temperature Superconducting FilmsMoistureSuperconducting TapesTape Measurements
We introduce a non‑destructive, contact‑free reel‑to‑reel apparatus for measuring the critical current of coated conductor tape. The apparatus passes up to 100 m of tape at 10 mm s⁻¹ through a sensor head in liquid nitrogen, then warms to room temperature to prevent condensation, and optionally employs a Hall probe array or an ac‑measurement coil to detect critical current, with calibration performed by transport measurement. In a 10 mm wide coated conductor, up to 400 A of critical current can be measured.
We introduce an apparatus for non-destructive, contact free, reel-to-reel critical current measurement of coated conductor tape. Up to 100 m of tape can be passed in front of a sensor head for the measurement in liquid nitrogen. The tape is transferred and characterized at a speed of 10 mm s−1. After the liquid nitrogen passage it is actively heated up to room temperature to avoid moisture condensation. Two different sensors in the probe head can be optionally activated: a linear Hall probe array in a field coil and an ac-measurement coil picking up third harmonic signals from the film. Once calibrated by transport measurement this arrangement enables characterization of HTS films on magnetic as well as on non-magnetic metal tape substrates. In a 10 mm wide coated conductor, up to 400 A of critical current can be measured.
8
YBaCuO-deposition on metal tape substrates
J. Knauf, R. Semerad, W. Prusseit et al. · IEEE Transactions on Applied Superconductivity · 2001 · 28 citations
Natural Sciences, Materials Engineering, Materials Science +17