Blood pressure assessment in haemodialysis patients: Comparison between pre‐dialysis blood pressure and ambulatory blood pressure measurement

Riccardo Maria Fagugli, Daniela Ricciardi, D Rossi, Andrea De Gaetano, Chiara Taglioni

Nephrology · 2009 · 16 citations · 31 references

Concepts

Abstract

AIM: Hypertension is common in haemodialysis (HD) patients. Determining the most appropriate method of blood pressure (BP) measurement, representative of target organ damage, is still an issue. BP variations between pre- and post-HD treatment, or between on-dialysis day and off-dialysis day, are common. The aim of this study was to examine the possible differences between pre-HD office BP (OBP) levels, inter-HD (iHD) or HDday 24 h ambulatory BP measurement (ABPM) with 48 h ABPM, where the latter was considered the gold standard. METHODS: 163 HD patients were studied. BP was monitored consecutively for 48 h with a Takeda TM2421 device, then sub-analysed into two periods of 24 h: HD and iHD day. An average of 12 sessions pre-HD OBP measurements was determined. RESULTS: OBP significantly overestimates systolic (SBP) and diastolic BP (DBP) when compared with 48 hABPM. SBP and DBP are significantly higher on iHD day than on HD day: 141.2 1 20.8 versus 137.9 1 20.9, and 77.1 1 11.1 versus 76.1 1 10.9 (P < 0.01). No differences of SBP night/day ratio were reported between 48 hABPM and iHD 24 h ABPM or HD 24 h ABPM. The highest correlations were reported between 48 h SBP/DBP with iHD or HD 24 h ABPM (r 2 = 0.95, P < 0.001), while the lowest between 48 h SBP/DBP and OBP (r 2 = 0.40,P < 0.01, r 2 = 0.12, P < 0.01). The narrowest limits of agreement using the Bland and Altman test were reported between 48 h SBP or DBP and 24 h iHD or HD day ABPM. Considering 48 h ABPM, 80.5% of patients had BP higher than the norm, compared with 61.7% of patients in the case of OBP (c2 = 13.28, P < 0.001). The sensibility for detecting hypertension for iHD day 24 h ABPM was 98.4%, with specificity of 90%. The sensibility of 24 h HDday ABPM was 90.3%, with specificity 96.6%. In the case of OBP, sensibility and specificity were considerably lower, that is, 72.6% and 83.3% respectively. CONCLUSION: Significant differences are shown between OBP and 48 h ABPM in the recognition of a hypertensive state. OBP measurement has a lower sensibility and specificity than 24 h ABPM, which remains a valid alternative approach to 48 h ABPM in HD patients. Errors of OBP estimation should be taken into account, with possible negative impact on treatment strategies and epidemiology studies

References

31