COMPARISON OF PROBE METHODS FOR MEASUREMENT OF BUBBLE PROPERTIES

Keun Ho Choi, Won Kook Lee

Chemical Engineering Communications · 1990 · 19 citations · 16 references

Concepts

Abstract

Abstract Direct quantitative comparisons of four different probe methods were performed for determination of local gas holdup, vertical bubble length, bubble rising velocity, and bubble frequency. The methods include vertically projecting electroresistivity, horizontally projecting electroresistivity, U-shape light reflection, and light transmission. The measured bubble properties strongly depended on the size and configuration of the probe tips. The light transmission probe developed in this work can be used to determine the bubble properties effectively. In order to minimize interferences with bubble flow, the size of probe tip should be small as possible and its configuration must be vertically projecting. KEYWORDS: Electrical probeOptical probeTip sizeTip configurationBubble properties. Additional informationNotes on contributorsWON KOOK LEE To whom all correspondence should be addressed.

References

16