The Journal of the Acoustical Society of America · 2002 · 48 citations · 7 references
Optical MaterialsEngineeringMicroscopySonoluminescenceBiomedical EngineeringEmbryologyMorphological ChangesBiophysicsHistopathologyAtomic PhysicsMason HornUltrasoundCell EngineeringUltrastructureAtomic Force MicroscopiesApplied PhysicsScanning Force MicroscopyOptical TrappingNanofabricationMedicine
Optical and atomic force microscopies were used for investigating morphological changes of Jurkat lymphocytes, which showed sonoporation after being exposed to a vibrating Mason horn tuned to 21.4 kHz for 2 min. The tip of the Mason horn had a diameter of 400 μm and its transverse vibration amplitude was 7.8 μm. It was found that immediately after sonification, some cells became irregular in shape but still more or less maintained their sizes, and other cells appeared to be much smaller than their normal sizes.