Proceedings of the Institution of Electrical Engineers · 1969 · 38 citations · 6 references
EngineeringElectrical EngineeringElectric MachinesMachine DesignPower ElectronicsElectric MotorsInduction MachinesInsulation SystemsLinear Electric MachinesLosses In Electric MachinesMagnetic Circuit AnalysisAir Gap AnalysisEquivalent Circuit AnalysisInduction MotorsIron LossesLinear Induction MotorsMotor LossesSkew EffectsSlip Characteristics
The paper presents an analysis of stray losses in polyphase cage-induction motors, under linear and saturation magnetisation conditions, with particular attention being given to the effects of circumferential currents flowing in the rotor as a consequence of imperfect bar-iron insulation. Such effects are included in a modified equivalent circuit of the motor, and are expressed in terms of factors readily determined from a set of normalised curves, not previously available. For example, the consequent reduction in the effective skew of the rotor bars can be determined, and thus a more correct evaluation obtained for those factors and losses dependent upon the resultant skew. Also, a simple graphical method is given for determining the effective increase of the air gap due to main-flux saturation, which assists in demonstrating that favourable agreement between the predicted and experimental torque/slip characteristics can be obtained with some reduction of the empiricism employed hitherto.
6