Abstract

The suitability of a commercially available, compressed-gas-insulated, high voltage capacitor for precise measurement of ac voltages has been examined by national laboratories in the U.S.A. and Canada. The voltage, temperature, and pressure dependences and the mechanical stability of the capacitor were determined. It was found that by taking proper precautions the device is competitive with other methods. As a result of this research, it was also found that high voltage capacitance measurements at the two laboratories involved are in agreement.