Effect of an axial magnetic field upon the development of the vacuum arc between opening electric currents (currents read contacts)

M.B. Schulman, Paul G. Slade, J. Heberlein

IEEE Transactions on Components Hybrids and Manufacturing Technology · 1993 · 107 citations · 19 references

Concepts

Abstract

In one series of experiments, a constant axial magnetic field B/sub ax/ was produced in the gap between opening Bruce-profile, chromium-copper contacts. Peak arc currents up to 40 kA at 50 Hz were studied with B/sub ax/ u to 112 mT. For each peak current, a critical field B/sub crit/ was determined above which anode spots did not form. For B/sub ax/ greater than B/sub crit/, the time from contact parting to the formation of a diffuse vacuum arc was linearly dependent on separation current. In a second series, the contacts were designed to generate a self B/sub ax/ when AC current up to 123 kA peak flowed. This field was approximately proportional to the current waveform through the contacts, and it was always higher than the B/sub crit/ predicted for the instantaneous current. The time from contact parting to the formation of the diffuse arc was consistent with that observed in the first experimental series. Once the diffuse arc had formed, the contacts showed no distributed melting for currents up to 81 kA, but gross melting occurred at 102-123 kA. The formation of diffuse arcs is discussed, and the anode melting is explained.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

References

19