Journal of Proteome Research · 2005 · 20 citations · 23 references
Life SciencesBiochemistryMolecular BiologyAnalytical ChemistryMass Spectrometric AnalysisProteomicsAffinity ChromatographyChromatographyMass SpectrometryPeptide AnalysisProtein SeparationDigestionImmobilized Metal Affinity ChromatographyMass Spectrometric DetectionMatrix-assisted Laser Desorption Ionization Time-of-flight Mass SpectrometryMatrix-assisted Laser Desorption/ionizationMiniaturized Sample HandlingPeptide Mass SpectrometryPeptide Separation
We describe a microspot matrix-assisted laser desorption ionization (MALDI) mass spectrometric approach to analyze gel-separated phosphoproteins. This method involves in-gel digestion of phosphoproteins after gel separation, followed by open tubular capillary (OTC) immobilized metal-ion affinity chromatography (IMAC) to capture the phosphopeptides with markedly reduced interferences from nonphosphorylated peptides. Nanoliter-volume of ammonium phosphate is used to elute the phosphopeptides captured on the capillary tube. After mixing with a small volume of matrix solution in the capillary, the effluent is deposited in a microspot on a sample plate for MALDI-MS analysis. It is also shown that, with peptide esterification after in-gel digestion of a phosphoprotein, negative ion detection in MALDI gives a distinct advantage over the positive ion mode of operation for phosphopeptide analysis, even without IMAC enrichment. However, the OTC-IMAC technique is demonstrated to be superior to the approach of negative ion detection of esterified in-gel digests without IMAC. OTC-IMAC is found to be sufficiently selective to capture phosphopeptides from in-gel digest of a gel band containing predominately one protein and the combination of peptide esterification and IMAC enrichment does not provide any real advantage. Using a standard phosphoprotein alpha-casein as a model system, we demonstrate that this OTC-IMAC method can detect a number of phosphopeptides after in-gel digestion with mid-fmol protein sample loading. An example of real world applications of this method is illustrated in the characterization of a fusion protein, His182, expressed in E. coli.
23
Mass Spectrometric Sequencing of Proteins from Silver-Stained Polyacrylamide Gels
Andrej Shevchenko, Matthias Wilm, Ole Vorm et al. · Analytical Chemistry · 1996 · 9.1K citations
Ole N. Jensen, Alexandre V. Podtelejnikov, Francis Sagliocco et al. · Proceedings of the National Academy of Sciences · 1996 · 1.4K citations
William J. Henzel, Todd M. Billeci, John T. Stults et al. · Proceedings of the National Academy of Sciences · 1993 · 1.3K citations