Concepedia

Publication | Closed Access

<title>Linear motion machine for soft x-ray interferometry</title>

11

Citations

0

References

1997

Year

Abstract

A Fourier Transform X-ray Spectrometer has been designed and built for use at the Advanced light source at Lawrence Berkeley National Laboratory. The design requires a total rectilinear motion of 15 mm with a maximum pitch error of the stage below {+-}0.4 {mu}radians, to achieve this the authors chose to build the entire machine as a single monolithic flexure. A hydraulic driver with sliding O-ring seals was developed with the intention to provide motion with a stick-slip position error of less than 0.8 nm at a uniform velocity of 20 {mu}m/sec. The machine is comprised of two pairs of nested linear motion flexures, all explained by means of a theory published earlier by Hathaway. Certain manufacturing errors were successfully corrected by an extra weak-link feature in the monolith frame. The engineering details of all the subsystems of the linear motion machine are described and measured performance reported.