Hip International · 2011 · 11 citations · 24 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBone GraftingJoint Replacement SurgeryOrthopedicsBone CementsHip ArthroplastyCemented Femoral FixationCemented FixationCementless Femoral FixationCementless FixationFemoral Component DesignFemoral Component FixationOutcome MeasuresUncemented Fixation
The current generation of metal-on-metal hip resurfacing designs has largely been characterized by cemented femoral fixation using a cementless cup. We present the clinical results of 135 entirely uncemented metal-on-metal hip resurfacing procedures. The primary outcome measures were revision for any cause and the Oxford hip score at the latest follow up. The average length of followup was 2.9 years. The mean Oxford hip score was 18.4 and no patient required revision of either component during the study period. Uncemented femoral fixation may be comparable to fixation with cement in metal-on-metal hip resurfacing.
24
Surgical dislocation of the adult hip
Reinhold Ganz, Emanuel Gautier, K. Ganz et al. · Journal of Bone and Joint Surgery - British Volume · 2001 · 1.3K citations
Adverse reaction to metal debris following hip resurfacing
David Langton, TJ Joyce, Simon Jameson et al. · Journal of Bone and Joint Surgery - British Volume · 2011 · 410 citations · Full text
Metal on Metal Surface Replacement of the Hip
Derek J. W. McMinn, R. B. C. Treacy, Kyaw Lin et al. · Clinical Orthopaedics and Related Research · 1996 · 409 citations