British Journal of Ophthalmology · 1989 · 25 citations · 12 references
MedicineOphthalmologyVeterinary OphthalmologyBiomedical ImagingDiagnostic ImagingOcular ImagingForeign Body DetectionForeign Body LocalizationForeign Body RetrievalIntraocular Foreign BodyIntraocular Foreign Body DetectionIntraocular Foreign Body InjuryIntraoperative Foreign Body LocalizationMagnetic Resonance Imaging Foreign Body DetectionOcular Foreign Body DetectionOcular Foreign Body ImagingOcular Foreign Body Injury
Magnetic resonance imaging was performed with a low field strength scanner (0.08 tesla) on 15 bovine eyes into which had been inserted various magnetic and non-magnetic foreign bodies. The precise location of the foreign bodies was determined by dissection. Magnetic resonance imaging was accurate in locating 11 of the 13 non-magnetic foreign bodies in this study. In addition a further five bovine eyes containing 10- to 20-mm long steel needles were scanned and dissected. No ocular damage attributable to movement of the foreign bodies could be seen.
12
Ferromagnetism of intraocular foreign body causes unilateral blindness after MR study.
W.M. Kelly, Patrick G Paglen, J.A. Pearson et al. · PubMed · 1986 · 146 citations · Full text