Applied Spectroscopy · 1992 · 65 citations · 12 references
Natural SciencesChemistryMaterials ScienceAnalytical ChemistryInstrumentationSpectroscopyFourier Transform SpectroscopyInfrared InstrumentationInfrared SpectroscopyOptical SpectroscopyTime-resolved SpectroscopyFerroelectric Liquid CrystalsFourier Transform Infrared SpectroscopyLow-pass FilteringPulse Generator CircuitsSpatial ReorientationSpectral DistortionTime ResolutionTime-resolved Infrared Spectroscopy
Existing FT‑IR time‑resolved methods require synchronization between the time‑resolving signal and the A/D sampling, whereas the new approach eliminates this requirement. The system employs a pulse generator, delay, gate, and low‑pass filter that can be attached to any conventional FT‑IR spectrophotometer, enabling observation of repetitive transient phenomena with lifetimes from about 1 μs to 1 ms. The asynchronous FT‑IR spectrophotometer delivers distortion‑free, artifact‑free spectra for fast repetitive phenomena, and was applied to ferroelectric liquid crystal reorientation, achieving a time resolution of 0.5 μs or better.
A novel asynchronous time-resolved FT-IR spectrophotometer based on a conventional continuous-scan interferometer has been developed. In contrast to the existing methods, this method does not require the synchronization between the signal for time resolving and that for the sampling of the A/D converter. The signal-processing assembly for time-resolved measurements consists of a pulse generator, a pulse delay circuit, a gate circuit, and a low-pass filter. This assembly can be attached to any conventional FT-IR spectrophotometer. By this method, time-resolved spectra without any spectral distortion or artifacts can be obtained for repetitive fast phenomena. As an application of this method, time-resolved FT-IR measurements have been carried out for the reorientation process in a ferroelectric liquid crystal induced by the reversal of external electric field, and a time resolution of 0.5 μs or less has been achieved. The present system is best suited for observing repetitive transient phenomena with lifetimes in the range from approximately 1 μs to 1 ms.
12
Fourier transform infrared spectrometry
D. E. Honigs · TrAC Trends in Analytical Chemistry · 1986 · 802 citations
R. N. Bracewell · Scientific American · 1989 · 527 citations
Time-Resolved FT-IR Absorption Spectroscopy Using a Step-Scan Interferometer
Wolfgang Uhmann, Andreas Becker, Christoph Taran et al. · Applied Spectroscopy · 1991 · 243 citations
L. A. Woodward · Contemporary Physics · 1960 · 82 citations