Step dB/dt magnetization losses in toroidal amorphous ribbon and polycrystalline cores

R.M. Jones

IEEE Transactions on Magnetics · 1982 · 12 citations · 2 references

Concepts

Abstract

The losses during step dB/dt pulse magnetization reversal in a practical sized toroidal core of Fe <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">81</inf> B <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">13.5</inf> Si <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3.5</inf> C <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> have been measured over a range of reversal rates. The variations in loss dissipation within the core have been monitored using search coil techniques for nominal reversal rates of 0.1 and 1.0 T/μs. The variations in loss dissipation are greater at high reversal rates than might be expected from a comparison with conventional materials and can be exolained in terms of reduced domain mobility in the amorphous specimen. The non-uniform loss distribution requires that close packing is achieved to enhance thermal transfer betweem adjacent wraps to prevent localised hot spots appearing.

References

2