Room Humidifiers as the Source of Acinetobacter Infections

Philip W. Smith

JAMA · 1977 · 94 citations · 5 references

Concepts

Abstract

Twenty-four patients contracted systemic infections with Acinetobacter calcoaceticus during a four-month period. Unheated room humidifiers at the patients' bedsides were implicated as the source of infection in six. The outbreak was terminated with the removal of the humidifers.

References