Effect of <mml:math altimg="si1.gif" display="inline" overflow="scroll" xmlns:xocs="http://www.elsevier.com/xml/xocs/dtd" xmlns:xs="http://www.w3.org/2001/XMLSchema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.elsevier.com/xml/ja/dtd" xmlns:ja="http://www.elsevier.com/xml/ja/dtd" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:tb="http://www.elsevier.com/xml/common/table/dtd" xmlns:sb="http://www.elsevier.com/xml/common/struct-bib/dtd" xmlns:ce="http://www.elsevier.com/xml/common/dtd" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:cals="http://www.elsevier.com/xml/common/cals/dtd"><mml:mi>σ</mml:mi></mml:math>-phase embrittlement on fatigue behaviour in high-chromium ferritic stainless steel

Takayuki Yamagishi, Masayuki Akita, Masaki Nakajima, Yoshihiko UEMATSU, Keiro TOKAJI

Procedia Engineering · 2010 · 33 citations · 7 references

DOIFull text

Open access

Concepts

Abstract

When ferritic stainless steels are exposed to the temperature range of 700–800 °C, embrittlement takes place, which is known as the σ-phase embrittlement. In the present study, axial fatigue tests were conducted using a high-chromium ferritic stainless steel, type 447 with the chromium content of 30.7%, which was aged at 750 °C for 150h and 300h, and the effect of σ-phase embrittlement on the fatigue behaviour was discussed. Vickers hardness increased significantly by aging due to the precipitation of hard σ-phase. The aged specimens exhibited much lower fatigue strengths than the un-aged one, where fatigue strength decreased with increasing aging time. The precipitation of brittle σ-phase reduced the crack initiation and growth resistances, resulting in the lower fatigue strengths of the aged specimens.