Knee Surgery Sports Traumatology Arthroscopy · 2009 · 24 citations · 33 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryJoint Replacement SurgeryOrthopedicsArthroscopic SurgeryJoint Motion AnalysisKnee ArthroplastyOsteoarthritisRange Of Motion RestorationFunctional Outcomes After ArthrodesisJoint Stiffness AssessmentKnee Function AssessmentKnee Range Of MotionKnee Stiffness
Twenty-two total knee replacements (TKR's) were treated for stiffness with arthroscopy and arthrolysis. The median follow-up was 38 months. No patients were lost to follow up. Extensive scarring was found and debrided in all of the knees. The mean Oxford Knee Score improved from 42.6 (+/-7.5) to 36.3 (+/-8.5) (P < 0.05) with TKR and from 36.3 (+/-8.5) to 29.3 (+/-9.0) (P < 0.05) with arthroscopic arthrolysis. The mean arc of motion improved from 8-69 degrees post-TKR to 3-105 degrees on table, but declined slightly to 4-93 degrees (P < 0.05) at most recent review. Arthroscopic arthrolysis compares well with other methods of treatment for stiffness with regard to improvements in range of motion and functional knee scores.
33
PREDICTING RANGE OF MOTION AFTER TOTAL KNEE ARTHROPLASTY
Merrill A. Ritter, Leesa D Harty, Kenneth Davis et al. · Journal of Bone and Joint Surgery · 2003 · 402 citations