Collection methods and contamination of bank milk.

Jon E. Tyson, W.H. Edwards, A M Rosenfeld, A. E. Beer

Archives of Disease in Childhood · 1982 · 27 citations · 5 references

DOIFull text

Open access

Concepts

Abstract

Bank milk collected by manual expression was less likely to be contaminated than milk collected by other methods. Contamination with coliforms and gentamicin-resistant Gram-negative rods was related to the pumps used by donors in their homes. Stringent precautions reduced but did not eliminate contamination.

References

5