Journal of Applied Sciences and Environmental Management · 2011 · 19 citations · 8 references
Natural ResourcesEnvironmental SciencesWater Quality EngineeringWater Quality ManagementWater TreatmentEnvironmental SanitationMunicipal Water TreatmentWater ManagementWater PollutionWater QualityWater SanitationColiform BacteriaDistribution Storage ReservoirsDistribution System Water QualityMicrobial Water ContaminationPhysicochemical Quality AttributesTurbidityWater Quality ContaminationWater Quality Investigation
The study was undertaken to examine water quality in the distribution network of Kampala City by assessing five storage reservoirs and four consumer taps. The aim was to evaluate residual chlorine decay andrelate it to the risk of recontamination. Physicochemical quality of water in the distribution network was temperature 25.6(24.23-28.66) pH 6.6 (6.5-7.1); turbidity 1.9 (0.5-4.5) NTU; colour 17.2 (2.0-54) PtCo, ammonia0.02 (0.0-0.05) mgl-1, and Fe2+ 0.005 (0-0.0.08) mgl-1. Residual chlorine decay was significant between the Water Treatment Plant (WTP) and the storage tanks (Total Chlorine, F=35.67, P< 0.05; Free Chlorine, F=37.97, P
8