Organic Letters · 2003 · 148 citations · 6 references
Life SciencesBiochemistryBiosensorsHormone BiochemistrySalivary DiagnosticsPhosphate HomeostasisPka DeterminationCalcium Phosphate ContentColorimetric BiosensorsColorimetric SensingColorimetric TestsPhosphate Ion DetectionReceptorsSalivary Phosphate ConcentrationSynthetic Receptors
[structure: see text] A C(3)(v) symmetric synthetic receptor (1) was employed in an indicator-displacement assay to determine the phosphate concentrations in both horse serum and human saliva at biological pH. The determination of the phosphate concentrations in the serum and saliva using the colorimetric assay were 1.6 and 5.1 mM, respectively. These results further accentuate the usefulness of synthetic receptors in truly practical applications.
6
Tietz Textbook of Clinical Chemistry
Archives of Pathology & Laboratory Medicine · 1999 · 2.5K citations
C.M. Carey, G.L. Vogel · Journal of Research of the National Institute of Standards and Technology · 2000 · 25 citations · Full text
Dentistry, Oral Biology, Biosensors +12