Journal of High Resolution Chromatography · 1995 · 16 citations · 4 references
Natural SciencesChemical EngineeringChemistryAnalytical ChemistrySpectroscopic AnalysisSpectroscopyAtomic Emission SpectroscopyCombustion AnalysisEmission SpectroscopyFuel ChemistryGas ChromatographyInstrumental AnalysisAdditivesAnalytical Detection LimitsAtomic Emission SpectrometryOxygen Content AnalysisOxygen DeterminationOxygenated FuelsOxygenated Volatile Organic CompoundsVolatile Organic Compound Detection
Abstract A GC method for the determination of oxygenated additives in reformulated gasolines (RFG) is described. The method uses on‐column injection and atomic emission selective detection of oxygenates using the 777 nm NIR emission line. Detection limits are approximately 10 ppm oxygen. Results compared well with other techniques, such as GC/FTIR.